| Pin number | Symbol | Level | I/O | Function | 
|---|---|---|---|---|
| 1 | Vss | - | - | Power supply (GND) | 
| 2 | Vcc | - | - | Power supply (+5V) | 
| 3 | Vee | - | - | Contrast adjust | 
| 4 | RS | 0/1 | I | 0 = Instruction input 1 = Data input | 
| 5 | R/W | 0/1 | I | 0 = Write to LCD module 1 = Read from LCD module | 
| 6 | E | 1, 1-->0 | I | Enable signal | 
| 7 | DB0 | 0/1 | I/O | Data bus line 0 (LSB) | 
| 8 | DB1 | 0/1 | I/O | Data bus line 1 | 
| 9 | DB2 | 0/1 | I/O | Data bus line 2 | 
| 10 | DB3 | 0/1 | I/O | Data bus line 3 | 
| 11 | DB4 | 0/1 | I/O | Data bus line 4 | 
| 12 | DB5 | 0/1 | I/O | Data bus line 5 | 
| 13 | DB6 | 0/1 | I/O | Data bus line 6 | 
| 14 | DB7 | 0/1 | I/O | Data bus line 7 (MSB) | 
| Pin number | Symbol | Level | I/O | Function | 
|---|---|---|---|---|
| 1 | DB7 | 0/1 | I/O | Data bus line 7 (MSB) | 
| 2 | DB6 | 0/1 | I/O | Data bus line 6 | 
| 3 | DB5 | 0/1 | I/O | Data bus line 5 | 
| 4 | DB4 | 0/1 | I/O | Data bus line 4 | 
| 5 | DB3 | 0/1 | I/O | Data bus line 3 | 
| 6 | DB2 | 0/1 | I/O | Data bus line 2 | 
| 7 | DB1 | 0/1 | I/O | Data bus line 1 | 
| 8 | DB0 | 0/1 | I/O | Data bus line 0 (LSB) | 
| 9 | E1 | 1, 1->0 | I | Enable signal row 0 & 1 | 
| 10 | R/W | 0/1 | I | 0 = Write to LCD module 1 = Read from LCD module | 
| 11 | RS | 0/1 | I | 0 = Instruction input 1 = Data input | 
| 12 | Vee | - | - | Contrast adjust | 
| 13 | Vss | - | - | Power supply (GND) | 
| 14 | Vcc | - | - | Power supply (+5V) | 
| 15 | E2 | 1, 1->0 | I | Enable signal row 2 & 3 | 
| 16 | n.c. | 
 
| Instruction | Code | Description | Execution time** | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RS | R/W | DB7 | DB6 | DB5 | DB4 | DB3 | DB2 | DB1 | DB0 | |||
| Clear display | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | Clears display and returns cursor to the home position (address 0). | 1.64mS | 
| Cursor home | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | * | Returns cursor to home position (address 0). Also returns display being shifted to the original position. DDRAM contents remains unchanged. | 1.64mS | 
| Entry mode set | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | I/D | S | Sets cursor move direction (I/D), specifies to shift the display (S). These operations are performed during data read/write. | 40uS | 
| Display On/Off control | 0 | 0 | 0 | 0 | 0 | 0 | 1 | D | C | B | Sets On/Off of all display (D), cursor On/Off (C) and blink of cursor position character (B). | 40uS | 
| Cursor/display shift | 0 | 0 | 0 | 0 | 0 | 1 | S/C | R/L | * | * | Sets cursor-move or display-shift (S/C), shift direction (R/L). DDRAM contents remains unchanged. | 40uS | 
| Function set | 0 | 0 | 0 | 0 | 1 | DL | N | F | * | * | Sets interface data length (DL), number of display line (N) and character font(F). | 40uS | 
| Set CGRAM address | 0 | 0 | 0 | 1 | CGRAM address | Sets the CGRAM address. CGRAM data is sent and received after this setting. | 40uS | |||||
| Set DDRAM address | 0 | 0 | 1 | DDRAM address | Sets the DDRAM address. DDRAM data is sent and received after this setting. | 40uS | ||||||
| Read busy-flag and address counter | 0 | 1 | BF | CGRAM / DDRAM address | Reads Busy-flag (BF) indicating internal operation is being performed and reads CGRAM or DDRAM address counter contents (depending on previous instruction). | 0uS | ||||||
| Write to CGRAM or DDRAM | 1 | 0 | write data | Writes data to CGRAM or DDRAM. | 40uS | |||||||
| Read from CGRAM or DDRAM | 1 | 1 | read data | Reads data from CGRAM or DDRAM. | 40uS | |||||||
| Bit name | Settings | |
|---|---|---|
| I/D | 0 = Decrement cursor position | 1 = Increment cursor position | 
| S | 0 = No display shift | 1 = Display shift | 
| D | 0 = Display off | 1 = Display on | 
| C | 0 = Cursor off | 1 = Cursor on | 
| B | 0 = Cursor blink off | 1 = Cursor blink on | 
| S/C | 0 = Move cursor | 1 = Shift display | 
| R/L | 0 = Shift left | 1 = Shift right | 
| DL | 0 = 4-bit interface | 1 = 8-bit interface | 
| N | 0 = 1/8 or 1/11 Duty (1 line) | 1 = 1/16 Duty (2 lines) | 
| F | 0 = 5x7 dots | 1 = 5x10 dots | 
| BF | 0 = Can accept instruction | 1 = Internal operation in progress | 
 
 
 
| Display size | Visible | |
|---|---|---|
| Character positions | DDRAM addresses | |
| 1*8 | 00..07 | 00h..07h | 
| 1*16 | 00..15 | 00h..0Fh | 
| 1*20 | 00..19 | 00h..13h | 
| 1*24 | 00..23 | 00h..17h | 
| 1*32 | 00..31 | 00h..1Fh | 
| 1*40 | 00..39 | 00h..27h | 
 
 
| Display size | Visible | |
|---|---|---|
| Character positions | DDRAM addresses | |
| 2*16 | 00..15 | 00h..0Fh + 40h..4Fh | 
| 2*20 | 00..19 | 00h..13h + 40h..53h | 
| 2*24 | 00..23 | 00h..17h + 40h..57h | 
| 2*32 | 00..31 | 00h..1Fh + 40h..5Fh | 
| 2*40 | 00..39 | 00h..27h + 40h..67h | 
 
 
| Display size | Visible | |
|---|---|---|
| Character positions | DDRAM addresses | |
| 4*16 | 00..15 | 00h..0Fh + 40h..4Fh + 14h..23h + 54h..63h | 
| 4*20 | 00..19 | 00h..13h + 40h..53h + 14h..27h + 54h..67h | 
| 4*40 | (00..39) on 1st controller and (00..39) on 2nd controller | (00h..27h + 40h..67h) on 1st controller and (00h..27h + 40h..67h) on 2nd controller | 
 
 

 


 